Address range 1 - 10239 (CV # 1 and CVs # 17, 18),
Consist addresses 1 - 127 (CV # 19),
14, 28 or 128 speed steps, alternatively; internally always 252 steps,
Noiseless motor control with 16 or 32 kHz ("high frequency"),
For special cases also "low frequency" available 30 - 200 Hz (CV # 9),
Back-EMF motor control for excellent low speed characteristics, 3-way adjustable (CVs # 10, 56, 58,113),
Ideally suitable for core less motors (Faulhaber, Maxxon, ...), emulates DC power, no excessive heat or noise.
Automatic adjustment to track voltage or definable voltage reference (CV # 57)
Acceleration and deceleration rates programmable as general, temporary or signal controlled,
Programmable exponential acceleration and deceleration for smooth behavior (CVs # 121 and 122).
Self-adaptive acceleration method to avoid abrupt transition from standstill to running (CV#123)
Shunting function, allows to switch off or to reduce the acceleration rates (momentum)
And apply half speed by a designated function key (CV # 124),
Simple speed table with start voltage, medium speed, high speed (CVs # 2, 6, 5) or ...
Factory installed nonlinear speed table or ...
Individual (user programmable) speed table with 28 steps (CVs # 67 - 94),
ZIMO´s "signal controlled speed influence", only if used within a ZIMO system (adjustable by CVs# 49-55)
Zimo’s “position controlled function influence”,only if used within a ZIMO system
Also supporting brake generators, negative DC signal and asymmetrical DCC signal (ABC) to stop trains,
Full function mapping according to NMRA RP 9.2.1 (CVs # 33 - 42, as applicable to a certain decoder),
Extended "ZIMO" function mapping for Swiss loco lighting, etc. (CV # 61),
Special American lighting effects, Mars, Strobe, Ditch, Gyra, Flicker (CVs # 125 - 128),
General voltage reduction output (dimming) by adjustable PWM operation (CV # 60),
Dimming, dipping, flashing, uncoupler control, assigned by programmable masks (CVs # 114 - 120),
Accepts LGB pulse chain commands
Analog and showcase mode (selectable functions in analog operation)
Service mode programming in all modes as defined by NMRA RP-9.2.3,
Operational mode programming ("on-the-main", "on-the-fly") for all configuration variables,
"Hard reset" by writing "8" into CV # 8 as proposed by future NMRA standard,
ZIMO's loco number identification, only if used within ZIMO system,
All decoders equipped with bidirectional communication
MX63, MX64 and MX69 with SUSI interface
Thermal protection
Overload protection on motor and functions outputs,
Avoiding decoder reset for short contact interruptions by special brownout method,
Uninterrupted driving on dirty track with external energy buffer, MX63, MX64 and MX69
Choose between 2 sets of stored CV tables for different conditions
User-activated software-update possible (EEPROM),
Insulated by adhesive film, shrink tube or heat sink.